Technical Analysis · Design & Structures
Trackers vs. Fixed Structures: Why the UNSW Study Forces You to Recalculate Deterioration Rates
📅 April 2026
⏱ Reading time: 7 minutes

PVclick Strategy Team
Operational and commercial analysis for the Italian PV sector
📊 0.35%/year Desert tracker | 📊 0.25%/year fixed desert | ☀️ 1.5× more UV on trackers |
🌡️ >80 W/m² UV in deserts | 📅 15 kWh/m² IEC threshold exceeded in 2 months
What you will find in this article
- The exact figures from the UNSW study and what they mean for your financial model
- When does it make sense to use a meter, and when is a flat rate really the better option?
- The 3 most widely used cell technologies (TOPCon, HJT) and how to request UV data from the manufacturer
- The technical checklist to be included in the specifications for systems in areas with high solar radiation
The figure that turns the business case on its head: 0.35% versus 0.25% per year
The practical result for designers is this: UV irradiance ranges from less than 30 W/m² at high latitudes to over 80 W/m² in deserts. At sites such as Alice Springs (Australia), a module reaches the cumulative UV threshold of 15 kWh/m² specified by the IEC 61215 standard for the entire qualification test. This is the same threshold that manufacturers declare as having passed the test.
📊 The key difference: In arid and tropical climates, single-axis trackers receive up to 1.5 times more UV radiation than fixed structures, with UV-induced degradation rates up to twice as high. Translated into P50 figures: 0.25–0.35%/year from UV alone, compared to the 0.25%/year typical of fixed systems in the same areas. In the words of Prof. Hoex: “Identical modules degrade differently depending on where they are installed.”
This changes the technical-economic comparison. A single-axis tracker typically produces 15–25% more energy than a fixed structure with the same modules and at the same site. But if you’ve lost an additional percentage point of efficiency by the fifteenth year, the advantage narrows. In “normal” sites (Southern Italy, mainland Spain, Greece), the tracker remains the winning choice. In extreme sites (North Africa, the Middle East, inland desert areas), the calculation must be redone using site-specific data.
The 4 technical factors you need to consider before choosing a configuration
1. Climate zone and actual UV spectrum
The IEC 61215 standard tests for 15 kWh/m² of cumulative UV radiation, a figure designed for temperate climates. In southern Sicily, the Ionian coast of Puglia, or southwestern Sardinia, a system reaches that threshold in about 10–14 months, not 25 years. You should ask the manufacturer for the results of extended UV tests, at least 60–100 kWh/m², not the standard minimum. Tier 1 manufacturers (LONGi, Trina, JA Solar, Jinko, AIKO) provide this data for utility-scale products upon request.
2. Cell technology: TOPCon and HJT are more sensitive
The UNSW study and parallel research by Fraunhofer ISE (December 2024) have documented that TOPCon and HJT exhibit higher UV sensitivity than traditional PERC, due to the passivation layer and hydrogen dynamics. These are precisely the technologies you are specifying today to maximize kWh/kWp yield. The real risk: gaining an efficiency advantage during the PAC phase and losing half of it by the tenth year.
Real mitigation measures available today: encapsulants with UV cutoff, front glass with anti-UV additives, and optimization of the passivation layer thickness as specified by the manufacturer. Request the technical data sheet for the EVA or POE used and verify that the transmittance is below 380 nm. For modules we import from leading Tier 1 manufacturers, you can consider the LONGi Hi-MO, JA Solar DeepBlue and AIKO ABC, all with extended UV reports available upon request.
3. Double-sided configuration: the double-sided risk
Bifacial modules also receive UV radiation on their rear side due to ground albedo (up to 25% on light-colored surfaces such as sand, gravel, and white roofs). On bifacial trackers in desert areas, total UV exposure can exceed that of a fixed monofacial system by 1.7–1.8 times. If you are designing a bifacial system on trackers, require the manufacturer to provide bifacial UV testing, not just the standard front-side testing.
4. Depreciation curve to be included in the business case
The total degradation of a module is not solely due to UV radiation; it includes LID, LeTID, thermal degradation, yellowing, and PID. UV radiation is one contributing factor. However, the standard practice of using a linear rate of 0.5% per year is becoming overly optimistic for sites with high irradiance. For desert/arid areas, use a two-phase curve: 2% in the first year, then 0.55–0.70%/year from the second to the twenty-fifth year. The UNSW model allows you to parameterize the site-specific UV contribution. In P90, 25-year production drops by 4–6% compared to what the standard Excel spreadsheet tells you today.
The Decision Matrix: When a Tracker Really Pays Off
When you combine the data on incremental energy efficiency and additional UV degradation, the decision becomes:
| Scenario | GHI (kWh/m²/year) | Recommended choice | Note |
|---|---|---|---|
| Northern Italy, Germany, Poland | 1,100–1,400 | Fixed | Tracker does not recoup CapEx, low UV |
| Central-Southern Italy, Spain, Greece | 1,600–1,900 | Tracker | IRR gap manageable with tested Tier 1 modules |
| Southern Spain, insular Greece, Sicily | 1,900–2,100 | Tracker with UV-enhanced modules | Specifications requiring mandatory extended UV testing |
| North Africa, Middle East, Chile | > 2,200 | Case-by-case evaluation | At some sites, a fixed system with more modules outperforms a tracker |
The operating principle: the higher the irradiance, the more inadequate the standard UV test becomes, and the more the tracker’s advantage erodes over the long term. This is not an argument against trackers; it is an argument in favor of stricter technical specifications when using them in extreme environments.
The checklist to add to your specifications today
If you are about to place an order for a system in an area with high solar radiation, here are the points we recommend including in the specifications before purchasing:
- Documented extended UV test: at least 60 kWh/m² cumulative, ideally 100 kWh/m², with photographic report and before/after IV curves
- Encapsulant declaration: brand, model, UV transmittance below 380 nm, IEC 61730 certificate of conformity
- For bifacial modules: separate back-side UV test, with bifaciality ratio verified after UV stress
- Revised performance warranty: maximum annual degradation clause applicable also to UV degradation, not just to “nominal” degradation
- Final flash test: verification of measured power with a positive tolerance of 0/+5 W, traceability by production batch
- For tracker-mounted systems: specific analysis using a site-specific UV model (such as the UNSW model) to be attached to the business case.
How PVclick helps you safeguard your 25-year business case
For utility-scale plants and large C&I projects, we take a different approach than traditional distribution. We import directly from Tier 1 manufacturers (LONGi, JA Solar, Trina, Jinko, AIKO, Canadian Solar), which allows us to obtain comprehensive technical data from the supplier—including enhanced UV testing—without going through intermediaries who simply resell you the standard datasheet.
For mounting structures and trackers, we apply the same approach: we work with leading Chinese manufacturers of bankable single-axis trackers and help you define the technical specifications based on the specific site, not a standard model.
The customer chooses between two service levels: Factory Connect, a direct connection to the factory at the most competitive price with your own customs management; or All Inclusive, a turnkey solution with customs, domestic transport, and WEEE disposal already included. The Italian team handles all technical and commercial aspects.
3 Things to Do This Week If You're Planning Projects in Areas with High Sunlight Intensity
- Open your latest utility-scale business case. If it uses a linear degradation rate of 0.5% per year in desert or pre-desert areas, recalculate using a curve of 2% in the first year and 0.6% per year thereafter. See what happens to your LCOE.
- Write to the manufacturer of the modules you are specifying and request the extended UV test report and the encapsulant data sheet. If they do not provide them within 72 hours, that is already a red flag.
- Separate the decision between trackers and fixed panels from the specific site. There is no such thing as “trackers are always better.” There is “at this site, with this module, and with this expected degradation, it is/is not cost-effective.”
The UNSW study does not dismiss trackers; it dismisses the idea that a standard technical data sheet and a linear degradation model are sufficient for a €20–30 million asset that must last 25 years. If you import directly, you have more leverage to obtain the data you need before signing.
Utility-scale projects in areas with high solar radiation?
Talk to our technical team: together, we’ll analyze your site and determine the most suitable modules and structure, using site-specific UV data provided by the manufacturer.